Key & Card
ACCESS control
the system use for more than only admission control
eMail: office@key card.com Tel. 0043(0)5522 38627
Key&Card D IGIcontrol-2000
· Central instrumentation
· Failure & assault alarm system
· Admission control
· Video monitoring
· Intercomsystem
· Light instrumentation
· Control engineering
Key &Card D IGIcontrol-2000
The intelligent instrumentation often commodity
Modern
building engineering is today hardly more conceivable without computer
engineering. ATS develops software and hardware within the area of intelligent
building engineering since 1980. Beginning with time registration and
admission control ATS continued the development with alarm -, video -,
Intercom and light control systems as well as intelligent energy management
and control systems consistently.
An
intelligent building system makes all decisions, in order to ensure the use of
the building with max. comfort and security with minimum consumption from
resources to. The demand of our time reads: maximal security and energy
conservation without each comfort loss. The solutions used so far were not up
to to this demand simply any longer. Only by the integration of all components
on Busebene, mentioned above, it was possible for ATS to come the ideal
conception of the intelligent building close.
Hardware
and software of the DIGIcontrol-2000 of system reflect the experience of ATS
as international enterprise of the intelligent safety and building
instrumentation against.
The
software
The
user surface of the 32Bit software is available both under Windows- 95/98
and under Windows NT/2000. The term user
surface is used as synonym and forms the general/comprehensive term for all
perceptible components of a computer for communication with your user. Humans
as users are located here in the focal point of all activities and are the
yardstick for the organization of communication with the system.
Base
of the user surface are the building plans displayed in high resolution. One
Conversion routine permits the transfer of pictures and building plans of each
CAD program. The diagram wordprocessor of the system enables the attachment of
supplements and corrections and an inserting from icons to the symbolic
representation of device statuses and functions. The clear diagram
representation of the building plans with the insertion of all desired events
and statuses permits a simple handling of the system to also untrained operating
personnel. Admission internal messages, door and device statuses, alarms and
measured values are displayed dynamically by color and representation
modification of the icons. In the case of an alarm or to request into the detail
diagram of the alarm area is switched automatically and a coordinated procedure
approach is inserted. If a video camera is assigned to the point of alarm, apart
from the activation of the video recorder recording the appropriate video signal
is inserted in the diagram picture. A lateral the diagram arrange window display
additional all still acknowledge alarm in Prioriaets and temporal sequence on.
Through
the individual device statuses know the simply clicking of the icons still to be
displayed more in detail or controlled. Becomes for example a Tuerikone, which
is assigned a camera and a Intercomstation, selected, takes place beside the
door status indication with instruction input fields also the automatic
combination and insertion appropriate life Video picture and the language
connection. A DIGI-2000 is ID card system integrated, an insertion of the photo
that can up-to-date admission-entitled person take place.
Almost
as many as desired diagram image planes enable a comfortable and simple
operation with their freely shapable icons the system. Extensive analyses and
logs complete the system and enable the optimization of flow controls.
Parameterizing of automatic functions under the individual subranges admission
control, alarm -, video -, Intercomsystem and control engineering, in addition,
from optionally mergable foreign trades, enables a functionality and an
efficiency, which possible one would have considered only in the next millenium.
The
network
As
head office an individual PC, in addition, a PC network can be used.
DIGIcontrol-2000 is usually implemented with a Windows NT file server and a WfW
3,11 or Windows-95 workstation. These are interconnected by so-called HUB's and
BRIDGE's and appropriate CAT-5 cable. Optionally also different networks can e.g.
Novell are used. Special one Communication modules permit the binding to other
systems and Host computer. Thus e.g. an automatic maintenance of the personnel
file can are implemented.
The
network head office attached over RS232 interface (DIGIcontrol-MU1000A22)
everything connects in that by a four-wire bus hardware components needed modern
building engineering. The network head office permits the link of 31 devices
over in pairs twisted a 4-Drahtbusleitung on a distance of up to 2000m. in place
of a device can a subexchange be attached in each case, those likewise 31
devices on a max. Length of 2000m connects. More than 900 devices and up to 5000
data points can be implemented in such a way in a network. Several networks can
be cared for of one or more leitwarten. Special network components such as RS232
or light conductor converters permit the extension of the network on almost any
distances.
Optically
separate ATS-ib interfaces permits the structure of against static unloadings
and differences of potential to insensitive networks. As network cables today
from the PC Netzwerktechnik common inexpensive CAT-5 cables are used.
The
integrated safety system
The
individual components
DIGIcontrol
IO The alarm system
forms those with its network function and the combined network and alarm
center Base of the intelligent building system. Extensive alarm and Event
functions can be programmed over the host often commodity. Automatic sharp
circuits over zeitfunktionen or anti-pass-bake Admission statuses can be
likewise implemented, like all in that Alarm technique usual functions. 255
global output relays and 255 global, two-colored LED statuses are available
network far. Beside the 16 Alarmeingaengen, which enable the link of 64
singleaddressable alarm units with in each case 4 differently resistances,
data points within max. 100 areas can be administered over the network up to
5000. As alarm entry INTERFACES units with in each case 8 or 32 are monitored
to inputs and alternatively 3 output relay at the disposal. Additionally the
alarm inputs in the admission and space monitoring units the available can be
used. All alarm inputs are locally parameterizable with filter functions.
Beside the alarm inputs also events from other trades can e.g. the admission
control than alarm trips serve.
DIGIlock-5000
The access control
system meets all desires to a modern and flexible electronic closing system.
According to standard up to 5000 cards in 6 time belts per weekday and holiday
per Tuere are administered. The system to 15,000 and max is optional. 300,000
cards expandable. All admission functions are locally administered. That is,
also in case of line interruption or failure of the host computer all
admission decisions without restriction can be met locally. Only if the host
computer system failed, even the anti-pass baking function becomes keep fully
upright. High suburb intelligence enables all Admission decisions inclusive
zone-anti-pass-bake within a tenth second to meet. Apart from the control of
the admission control readers, the door control station supports also alarm
entry handling, air-lock functions, fire messages as well as all
time-dependent door functions. ATS produces all usual card reader technologies.
Due to by ATS developed the contactless Proximity reader, with a price only
scarcely over that of the magnetic card reader, come as meaningful alternative
only more magnetic cards -, smart card and the " Hands free" reader
with ranges from 0,5 to 1,5m to the selection.
15
years experience with over 800 large installations in banks, airports,
industrie and research enterprises guarantee max. functionality and security
of the ATS access control system.
|
|
DIGIcontrol
VCW A video monitor, which
does not leave a desire of the operator open by its modular and fully structure
integrated in the ATS network. In the control post diagram selectable the
cameras with life video insertion and controlling of the swiveling tilting heads,
permit also the operation by untrained personnel. Heart of the video monitor is
the video crossbar DIGIcontrol-V3164K developed by ATS, which is attached
directly to the ATS-ib. It enables the combination of 64 cameras on max. 31
monitors in one only to 1çm high 19 " module. Add-on units enable an
extension to max. 512 cameras. With their dimensions and excellent electrical
characteristics is probably it the best video crossbar available at the market.
50
sequences with up to 50 cameras, camera and Alarmtexte, as well as alarm
macros can be stored in the crossbar. Its own video data bus permits that Link
of hand control desks with and without control sticks as well as own of ATS
developed swiveling tilting heads with local storing of 50 Positions and 10
movement programs. The call of the stored positions can be made both from the
graphic user surface and the hand control desks as well as by automatic alarm
functions.
Extensive addition components, like 2-
wire converter for color signals with ranges from up to 1800m, developed by ATS, multiplexer and video compression units to the video transfer over normal voice grade channels complete the program.One of the most standing out characteristics is the full integration into the ATS network. Thus is preserved also in case of failure of the host computer system the full functionality video system. That is called e.g. also the combination of cameras with alarm text insertion and swivels / slope positions with alarm clearing or unauthorized admission control attempts. Basically all information of the network can be used for the clearing by video switching operations.
DIGIcontrol-2000
Building
engineering for sake the environment sake
DIGIcom-2000
The integrated
Intercomsystem is implemented by the Intercomzentrale DIGIcom-2000Z attached to
the ATS-ib. The fundamental unit supports 32 substations and can with modules in
steps of 32 on up to 512 substations be developed. For communication are desk
and door substations as well as loudspeaker modules to order. Owing to the
sophisticated language control an unsurpassed language quality is achieved.
The
door substation as visiting card of each building found the special attention of
the ATS Design department. A modular concept with resistant powder-coated
aluminum framework enables the non-standard organization to the door substation.
A LCD Farbmonitormodul enables the configuration to an exclusive wall
substation.
The
display integrated into the desk substation displays, who calls, for recall
waits, does not want not to be disturbed, is filled or absent. An inserted clock
permitted pre-programmed connections and memory displays. By the integration
with the building system DIGIcom-2000 is also automatically informed about
absences or necessary rufumleitungen. Search calls for persons become only into
that, due to which admission control information infragekommenden areas
activates. Of course also information of the ATS Zeiterfassungssystems
DIGItime-2000 is processed.
An
optional speaking and selecting card permits the storage of 8 announcements and
the rufumleitung to the telephone PABX. All events in the network can be used
for the clearing of stored alarm announcements to a certain group or to all.
The
video option permits the extension of the system with video substations and
monitoring cameras. Per module 2 video channels are available, on which up to 31
different cameras by means of interlock casings or door act ions can be attached.
DIGIcontrol
LC The ATS light control
system enables the implementation of all demands made against the modern
building engineering by its flexible structure. The network and control unit
DIGIcontrol-MU260 permit the control of 70 local light output units per
Unterstation with in each case up to 31 input modules with 4 inputs each. Over
1000 light sets can be headed for by schaltmodulen, IR Bewegungsmeldern, time
programs and other events in the network. Over the network distributed light
output units (relay outputs in addition, triacs) are linked with the light sets.
If a light switch is to head for another lighting or lighting's group, then this
is parameterizable over the instrumentation within seconds. The combined use
from IR Alarmdetektoren to switching on of the lighting on with darkness and
movement, as well as the automatic time-delayed disconnection of the sources of
light, in no more used spaces, saves cash and valuable resources. Past are the
times, where in the darkness for the light switch had to be looked up. Light
switches only more for over-regulation functions e.g. with dia. lectures etc.
are needed. Light switches with " entirely out " function or with call
of special light sequences in conference rooms can be implemented with simple
inputs of the operator. Over DIGIcontrol-DM2 entered current peaks and counter
values can be used for the automatic disconnection of necessarily necessary
consumers. Performance specification with Lichtausgangstreibern, enables an
allocation of the energy costs entered with the DIGIcontrol-DM2 to module. Relay
output units with analogue inputs permit the implementation of special tasks.
DIGIcontrol LC and its components represent today the most efficient method for
the increase of the use comfort during an energy conservation of up to 30%.
Continuous recordings of the energy consumption enable a further optimization.
DIGIcontrol RE Control engineering of ATS is characterised by consistent application of the individual room regulation technique. This in the acquisition most expensive control engineering enables the most effective way to the energy conservation. By the integration into the Netwerk the single room automatic controller receives all for optimal regulation to needed data. The DIGIcontrol-ER2000 single room automatic controller in Kombination with the space monitoring unit DIGIlock-500NA/RC is the base of the probably most efficient system of the modern building engineering. By the Integration everything in einem space needed functions such as admission control, Alarm
control, light control & temperature control places it a compact and cost effective solutionA
more efficient space monitoring unit than ATS DIGIlock-500NA/RC is not to be
found at present at the market. But the many functions for itself alone regarded
are not the most important. Is from special interest only the Moeglichkeiten,
which can be erziehlt by the combination of all functions in the
DIGIcontroll-2000 system. All information such as space use, ambient
temperatures, energy production by activated lighting as well as the behavior of
the building users finds input into the energy optimization. The clear
representation and logging of all temperatures and stabilization factors in the
head office make building instrumentation the pleasure.
|
Building management - software |
|||||||||||||||||||||||||||||||||||||||||||
|
Building management - Admission control
|
|||||||||||||||||||||||||||||||||||||||||||
|
Building management - system approaches
|
|||||||||||||||||||||||||||||||||||||||||||
|
Gebaeudemangagement - Video monitoring
|
|||||||||||||||||||||||||||||||||||||||||||
|
Gebäudemanagement - Alar mcontrol
|
|||||||||||||||||||||||||||||||||||||||||||
|
Gebäudemanagement - Kommunikation |
|||||||||||||||||||||||||||||||||||||||||||
|
Gebäudemanagement - Hausleittechnik
|
|||||||||||||||||||||||||||||||||||||||||||
|
Gebäudemanagement - Zeiterfassung
|